Ecoflex 10 FRNC coaxial cable 50 Ω, Ø10.2 mm, FRNC/LSZH, Cca, black, K505

Price:

7.89 €


​ Hinnat ovat ALV 0%. ​ B2B-hinnat ja tarjoukset kirjautumalla
DVI-D-cable 24+1 Clicktronic Casual
DVI-D-cable 24+1 Clicktronic Casual
19.42 €
19.42 €
XLR3-female/6.3-male stereo KLOTZ black M1 Prime balanced
XLR3-female/6.3-male stereo KLOTZ black M1 Prime balanced
16.80 €
16.80 €

Ecoflex 10 FRNC coaxial cable 50 Ω, Ø10.2 mm, FRNC/LSZH, Cca, black, K505

https://www.tele-tukku.fi/web/image/product.template/77029/image_1920?unique=552bb34

SSB

Low-loss, flexible 50 Ω coaxial cable for antenna and RF connections at frequencies up to 6 GHz. The copper inner conductor and halogen-free FRNC jacket are suitable for building cabling requiring CPR class Cca. Halogen-free, low-smoke and UV-resistant FRNC jacket.

  • Ø10.2 mm · CPR Cca-s1,d0,a1 · FRNC/LSZH · black
  • Attenuation 13.49 dB / 100 m at 1 GHz
  • Sold by the metre. Standard reel: 505 m (K505).

7.89 € 7.890000000000001 EUR 7.89 €

Not Available For Sale


  • Brand
  • Color
  • Material
  • Impedance
  • Cable Outer Diameter
  • Cable Type
  • CPR Classification
  • Conductor Type
  • Reel Length (m)
  • Inner Conductor Diameter
  • Conductor Material
  • Outer Conductor Diameter
  • Shielding
  • Frequency
  • Attenuation
  • Mounting Location

This combination does not exist.



SKU :
EFL10FRNC505
Tags :
Share :

Ecoflex 10 FRNC – technical specifications and applications

Low-loss, flexible 50 Ω coaxial cable for antenna and RF connections at frequencies up to 6 GHz. The copper inner conductor and halogen-free FRNC jacket are suitable for building cabling requiring CPR class Cca.

Foamed polyethylene insulation reduces transmission losses. Copper foil and copper braid provide double shielding to reduce the effect of external interference on the signal. Halogen-free, low-smoke and UV-resistant FRNC jacket.

Construction and dimensions

  • Outer diameter: Ø 10.2 ± 0.2 mm
  • Inner conductor: Ø 2.85 mm; stranded copper (OFC), 7 × 1.0 mm (10 AWG)
  • Dielectric: foamed PE with skin, Ø 7.2 mm
  • Shielding: overlapping copper foil, 100% coverage; copper braid, 75% coverage
  • Outer conductor diameter: Ø 7.9 mm
  • Jacket: FRNC/LSZH, black
  • Weight: 136 g/m (136 kg/km)
  • Supply: sold by the metre; standard reel 505 m (K505)

Electrical properties

Values at +20 °C unless otherwise stated.

  • Impedance: 50 ± 2 Ω
  • Maximum operating frequency: 6 GHz
  • Capacitance: 78 pF/m (1 kHz)
  • Velocity factor: 0.85
  • Shielding attenuation: ≥ 90 dB at 1 GHz
  • DC resistance: inner conductor ≤ 3.5 Ω/km; outer conductor 6.6 Ω/km
  • Insulation resistance: ≥ 10 GΩ·km
  • Test voltage: 7 kV DC (inner conductor–shield)
  • Maximum voltage: 5 kV

Attenuation by frequency

Typical attenuation in dB / 100 m at +20 °C.

100 MHz: 3.8500 MHz: 9.121000 MHz: 13.492400 MHz: 22.423000 MHz: 25.376000 MHz: 37.05
All 20 attenuation values (5–6000 MHz)
5 MHz: 0.7610 MHz: 1.1450 MHz: 2.66100 MHz: 3.8144 MHz: 4.66200 MHz: 5.51300 MHz: 6.94432 MHz: 8.46500 MHz: 9.12800 MHz: 11.881000 MHz: 13.491296 MHz: 15.681500 MHz: 17.011800 MHz: 18.912000 MHz: 20.142400 MHz: 22.423000 MHz: 25.374000 MHz: 29.555000 MHz: 33.446000 MHz: 37.05

Example: the calculated attenuation of a 25-metre cable at 1 GHz is approximately 3.37 dB. Connector losses are additional.

Power handling

Maximum power in watts at +40 °C, as specified by the manufacturer.

100 MHz: 1210 W500 MHz: 510 W1000 MHz: 350 W2000 MHz: 230 W2400 MHz: 210 W3000 MHz: 180 W6000 MHz: 120 W

Installation and operating conditions

  • Minimum bend radius: 4 × outer diameter for a single bend; 8 × outer diameter for repeated bending
  • Temperature, transport and fixed installation: −55…+85 °C
  • Temperature, mobile use: −40…+85 °C
  • Maximum tensile force: 600 N
  • Installation: indoor and outdoor use; UV-resistant jacket

Select 50 Ω connectors sized for Ecoflex 10 FRNC cable and follow the connector manufacturer’s stripping and assembly instructions. Protect outdoor connections against moisture and avoid crushing the cable.

Fire classification and documents

  • CPR fire class: Cca-s1,d0,a1 (EN 50575)
  • Jacket properties: halogen-free, low-smoke, flame-retardant (FRNC/LSZH)

Manufacturer’s technical data: SSB Ecoflex 10 FRNC . Product-specific attachments are also available on the Documents tab.

General
Brand SSB
Tekniset tiedot
Color Black
Material LSZH
Impedance 50 ohm
Cable Outer Diameter Ø 10.2 mm
Cable Type Ecoflex 10
CPR Classification Cca
Conductor Type Stranded conductor
Reel Length (m) CUT maksu 505 m
Inner Conductor Diameter 2,85 mm
Conductor Material Kupari
Outer Conductor Diameter 7,9 mm
Shielding Kuparifolio + kuparipunos
Frequency Enintään 6 GHz
Attenuation 13,49 dB/100 m @ 1 GHz
Mounting Location Sisä- ja ulkokäyttö
Datasivu EcoFlex 10 FRNC.pdf
Download