Aircell 7 coaxial cable 50 Ω, Ø7.3 mm, PVC, Eca, black, K505

Price:

4.26 €


​ Hinnat ovat ALV 0%. ​ B2B-hinnat ja tarjoukset kirjautumalla
MaxiMag magnetic base ball joint M6 thread 27-1000 MHz LL58 3.65 m cable FME-female connector
MaxiMag magnetic base ball joint M6 thread 27-1000 MHz LL58 3.65 m cable FME-female connector
79.30 €
79.30 €
CAT8.1 S/FTP LSZH CU black patch cable
CAT8.1 S/FTP LSZH CU black patch cable
9.18 €
9.18 €

Aircell 7 coaxial cable 50 Ω, Ø7.3 mm, PVC, Eca, black, K505

https://www.tele-tukku.fi/web/image/product.template/70207/image_1920?unique=f026742

SSB

Flexible 50 Ω coaxial cable for antenna and RF connections at frequencies up to 6 GHz. The stranded copper conductor makes installation easier along curved cable routes and in confined spaces. The UV-stabilised PVC jacket is suitable for indoor and outdoor installations.

  • Ø7.3 mm · CPR Eca · PVC · black
  • Attenuation 20.44 dB / 100 m at 1 GHz
  • Sold by the metre. Standard reel: 505 m (K505).

4.26 € 4.26 EUR 4.26 €

Not Available For Sale


  • Brand
  • Color
  • Material
  • Impedance
  • Cable Outer Diameter
  • CPR Classification
  • Conductor Type
  • Cable Type
  • Reel Length (m)
  • Inner Conductor Diameter
  • Conductor Material
  • Outer Conductor Diameter
  • Shielding
  • Frequency
  • Attenuation
  • Mounting Location

This combination does not exist.

Check availability
ETA week 43


SKU :
AIRCELL7505
EAN :
6416280460764
Share :

Aircell 7 – technical specifications and applications

Flexible 50 Ω coaxial cable for antenna and RF connections at frequencies up to 6 GHz. The stranded copper conductor makes installation easier along curved cable routes and in confined spaces.

Foamed polyethylene insulation reduces transmission losses. Copper foil and copper braid provide double shielding to reduce the effect of external interference on the signal. The UV-stabilised PVC jacket is suitable for indoor and outdoor installations.

Construction and dimensions

  • Outer diameter: Ø 7.3 ± 0.2 mm
  • Inner conductor: Ø 1.9 mm; stranded copper (OFC), 19 × 0.38 mm (14 AWG)
  • Dielectric: foamed PE with skin, Ø 5.0 mm
  • Shielding: overlapping copper foil, 100% coverage; copper braid, 85% coverage
  • Outer conductor diameter: Ø 5.7 mm
  • Jacket: PVC, black
  • Weight: 70 g/m (70 kg/km)
  • Supply: sold by the metre; standard reel 505 m (K505)

Electrical properties

Values at +20 °C unless otherwise stated.

  • Impedance: 50 ± 2 Ω
  • Maximum operating frequency: 6 GHz
  • Capacitance: 78 pF/m (1 kHz)
  • Velocity factor: 0.85
  • Shielding attenuation: ≥ 90 dB at 1 GHz
  • DC resistance: inner conductor ≤ 9 Ω/km; outer conductor 8.7 Ω/km
  • Insulation resistance: ≥ 10 GΩ·km
  • Test voltage: 10 kV DC (inner conductor–shield)
  • Maximum voltage: 8 kV

Attenuation by frequency

Typical attenuation in dB / 100 m at +20 °C.

100 MHz: 5.97500 MHz: 13.981000 MHz: 20.442400 MHz: 33.823000 MHz: 38.846000 MHz: 61.66
All 20 attenuation values (5–6000 MHz)
5 MHz: 1.5210 MHz: 2.0950 MHz: 4.29100 MHz: 5.97144 MHz: 7.22200 MHz: 8.59300 MHz: 10.64432 MHz: 12.92500 MHz: 13.98800 MHz: 18.051000 MHz: 20.441296 MHz: 23.61500 MHz: 25.731800 MHz: 28.52000 MHz: 30.292400 MHz: 33.823000 MHz: 38.844000 MHz: 46.665000 MHz: 54.196000 MHz: 61.66

Example: the calculated attenuation of a 25-metre cable at 1 GHz is approximately 5.11 dB. Connector losses are additional.

Power handling

Maximum power in watts at +40 °C, as specified by the manufacturer.

100 MHz: 620 W500 MHz: 260 W1000 MHz: 191 W2000 MHz: 131 W2400 MHz: 118 W3000 MHz: 104 W6000 MHz: 70 W

Installation and operating conditions

  • Minimum bend radius: 4 × outer diameter for a single bend; 8 × outer diameter for repeated bending
  • Temperature, transport and fixed installation: −55…+85 °C
  • Temperature, mobile use: −40…+85 °C
  • Maximum tensile force: 300 N
  • Installation: indoor and outdoor use; UV-resistant jacket

Select 50 Ω connectors sized for Aircell 7 cable and follow the connector manufacturer’s stripping and assembly instructions. Protect outdoor connections against moisture and avoid crushing the cable.

Fire classification and documents

  • CPR fire class: Eca (EN 50575)

Manufacturer’s technical data: SSB Aircell 7 . The product-specific data sheet and Declaration of Performance (DoP) are also available on the Documents tab.

General
Brand SSB
Tekniset tiedot
Color Black
Material PVC
Impedance 50 ohm
Cable Outer Diameter Ø 7.3 mm
CPR Classification Eca
Conductor Type Stranded conductor
Cable Type Aircell 7
Reel Length (m) CUT maksu 505 m
Inner Conductor Diameter 1,9 mm
Conductor Material Kupari
Outer Conductor Diameter 5,7 mm
Shielding Kuparifolio + kuparipunos
Frequency Enintään 6 GHz
Attenuation 20,44 dB/100 m @ 1 GHz
Mounting Location Sisä- ja ulkokäyttö